Sky Heating & Air Conditioning provides a wide range of quality HVAC services to homeowners across Portland and The Dalles.  By bringing together skilled technicians and premier products, we deliver superior value for your investment.  We utilize tried and true strategies to enhance efficiency, comfort, and convenience throughout your home.  For heating and air conditioning installation, repair, and regular maintenance, no one takes better care of you than Sky Heating & Air Conditioning.  And we’re always here!  Count on us 24 hours a day, 7 days a week, to protect your safety, comfort, and best interests.
Circulating refrigerant vapor enters the compressor, where its pressure and temperature are increased. The hot, compressed refrigerant vapor is now at a temperature and pressure at which it can be condensed and is routed through a condenser. Here it is cooled by air flowing across the condenser coils and condensed into a liquid. Thus, the circulating refrigerant removes heat from the system and the heat is carried away by the air. The removal of this heat can be greatly augmented by pouring water over the condenser coils, making it much cooler when it hits the expansion valve.
The first air conditioners and refrigerators employed toxic or flammable gases, such as ammonia, methyl chloride, or propane, that could result in fatal accidents when they leaked. Thomas Midgley, Jr. created the first non-flammable, non-toxic chlorofluorocarbon gas, Freon, in 1928. The name is a trademark name owned by DuPont for any chlorofluorocarbon (CFC), hydrochlorofluorocarbon (HCFC), or hydrofluorocarbon (HFC) refrigerant. The refrigerant names include a number indicating the molecular composition (e.g., R-11, R-12, R-22, R-134A). The blend most used in direct-expansion home and building comfort cooling is an HCFC known as chlorodifluoromethane (R-22).

Central home air conditioner service systems consist of two major components: a condensing unit that sits outside your house, and the evaporator coil (often referred to as an A-coil) that sits in the plenum of your furnace or air handler. The refrigerant in the A-coil picks up the heat from your home and moves it to the outdoor condensing unit. The condensing unit fan blows outside air through the condensing coil to remove the heat. The condensing unit houses the three parts replaceable by a DIYer: the contactor, the start/run capacitor(s) and the condenser fan motor. The condensing unit also houses the compressor, but only a pro can replace that. The A-coil has no parts that can be serviced by a DIYer.

While there's nothing you can do to guarantee your air conditioner or furnace will never need repairs, there are ways to take better care of your system. Changing out the air filters every 3-6 months, making sure nothing is obstructing or interfering with the outside unit, and keeping all vents unblocked in well-used rooms will help keep your air conditioning and heating system operating efficiently.
Next check and clean the furnace’s flame sensor. The video below shows you how—note that this guy fixes it in about 5 minutes. We would probably use a little bit of emory paper, but he cleans the sensor with a 5-dollar bill. Another video further down the page under the discussion of “If your furnace keeps shutting off after about 5 minutes” shows the same project with a different brand of furnace.

Inside the unit, the air passes over the evaporator coil first, and is cooled and dehumidified. The now dehumidified, cold air then passes over the condenser coil where it is warmed up again. Then the air is released back into the room. The unit produces warm, dehumidified air and can usually be placed freely in the environment (room) that is to be conditioned.


Many homeowners don't often think of the state of their furnace—that is until, the first cold day of the year comes around and the furnace won't turn on or only blows cold air. Keeping an eye out for common signs of trouble can help you avoid a complete furnace breakdown. Addressing any issues early on can also help you avoid most extensive (and therefore, more expensive) repairs down the road.
This is probably the most common question we hear. To give an accurate price, we need to get a safety certified technician out to your home in a fully stocked truck to take a look at your particular situation. Our technician will give you a precise price with your options BEFORE any work begins. Each of our technicians are well trained, experienced, drug tested and background checked so that you can rest easy knowing your services will be performed in a timely and professional manner. If you need help paying for your services, we even offer financing with approved credit through Wells Fargo. Click here to learn more about our financing services.
This is probably the most common question we hear. To give an accurate price, we need to get a safety certified technician out to your home in a fully stocked truck to take a look at your particular situation. Our technician will give you a precise price with your options BEFORE any work begins. Each of our technicians are well trained, experienced, drug tested and background checked so that you can rest easy knowing your services will be performed in a timely and professional manner. If you need help paying for your services, we even offer financing with approved credit through Wells Fargo. Click here to learn more about our financing services.
With the ice and snow in the Charlotte area this week be sure to look at your outdoor unit for ice or snow buildup, especially if you have a heat pump. You can carefully attempt to remove any frozen buildup by pouring warm water over the unit to melt the snow and ice. Do not use any sharp objects to pick or knock the ice off, this could cause severe damage to the unit

Absorption refrigerator Air barrier Air conditioning Antifreeze Automobile air conditioning Autonomous building Building insulation materials Central heating Central solar heating Chilled beam Chilled water Constant air volume (CAV) Coolant Dedicated outdoor air system (DOAS) Deep water source cooling Demand-controlled ventilation (DCV) Displacement ventilation District cooling District heating Electric heating Energy recovery ventilation (ERV) Firestop Forced-air Forced-air gas Free cooling Heat recovery ventilation (HRV) Hybrid heat Hydronics HVAC Ice storage air conditioning Kitchen ventilation Mixed-mode ventilation Microgeneration Natural ventilation Passive cooling Passive house Radiant heating and cooling system Radiant cooling Radiant heating Radon mitigation Refrigeration Renewable heat Room air distribution Solar air heat Solar combisystem Solar cooling Solar heating Thermal insulation Underfloor air distribution Underfloor heating Vapor barrier Vapor-compression refrigeration (VCRS) Variable air volume (VAV) Variable refrigerant flow (VRF) Ventilation
In the UK, the Ozone Regulations[62] came into force in 2000 and banned the use of ozone depleting HCFC refrigerants such as R22 in new systems. The Regulation banned the use of R22 as a "top-up" fluid for maintenance between 2010 (for virgin fluid) and 2015 (for recycled fluid). This means that equipment that uses R22 can still operate, as long as it does not leak. Although R22 is now banned, units that use the refrigerant can still be serviced and maintained.
In 1906, Stuart W. Cramer of Charlotte was exploring ways to add moisture to the air in his textile mill. Cramer coined the term "air conditioning", using it in a patent claim he filed that year as an analogue to "water conditioning", then a well-known process for making textiles easier to process. He combined moisture with ventilation to "condition" and change the air in the factories, controlling the humidity so necessary in textile plants. Willis Carrier adopted the term and incorporated it into the name of his company.[10]

In modern buildings, the design, installation, and control systems of these functions are integrated into one or more HVAC systems. For very small buildings, contractors normally estimate the capacity and type of system needed and then design the system, selecting the appropriate refrigerant and various components needed. For larger buildings, building service designers, mechanical engineers, or building services engineers analyze, design, and specify the HVAC systems. Specialty mechanical contractors then fabricate and commission the systems. Building permits and code-compliance inspections of the installations are normally required for all sizes of building.
In the case of heated water or steam, piping is used to transport the heat to the rooms. Most modern hot water boiler heating systems have a circulator, which is a pump, to move hot water through the distribution system (as opposed to older gravity-fed systems). The heat can be transferred to the surrounding air using radiators, hot water coils (hydro-air), or other heat exchangers. The radiators may be mounted on walls or installed within the floor to produce floor heat.
In 1820, English scientist and inventor Michael Faraday discovered that compressing and liquefying ammonia could chill air when the liquefied ammonia was allowed to evaporate. In 1842, Florida physician John Gorrie used compressor technology to create ice, which he used to cool air for his patients in his hospital in Apalachicola, Florida. He hoped to eventually use his ice-making machine to regulate the temperature of buildings. He even envisioned centralized air conditioning that could cool entire cities. Though his prototype leaked and performed irregularly, Gorrie was granted a patent in 1851 for his ice-making machine. Though his process improved the artificial production of ice, his hopes for its success vanished soon afterwards when his chief financial backer died and Gorrie did not get the money he needed to develop the machine. According to his biographer, Vivian M. Sherlock, he blamed the "Ice King", Frederic Tudor, for his failure, suspecting that Tudor had launched a smear campaign against his invention. Dr. Gorrie died impoverished in 1855, and the dream of commonplace air conditioning went away for 50 years.[citation needed]
The performance of vapor compression refrigeration cycles[24] is limited by thermodynamics. These air conditioning and heat pump devices move heat rather than convert it from one form to another, so thermal efficiencies do not appropriately describe the performance of these devices. The Coefficient-of-Performance (COP) measures performance, but this dimensionless measure has not been adopted. Instead, the Energy Efficiency Ratio (EER) has traditionally been used to characterize the performance of many HVAC systems. EER is the Energy Efficiency Ratio based on a 35 °C (95 °F) outdoor temperature. To more accurately describe the performance of air conditioning equipment over a typical cooling season a modified version of the EER, the Seasonal Energy Efficiency Ratio (SEER), or in Europe the ESEER, is used. SEER ratings are based on seasonal temperature averages instead of a constant 35 °C (95 °F) outdoor temperature. The current industry minimum SEER rating is 14 SEER.[25]
In variable climates, the system may include a reversing valve that switches from heating in winter to cooling in summer. By reversing the flow of refrigerant, the heat pump refrigeration cycle is changed from cooling to heating or vice versa. This allows a facility to be heated and cooled by a single piece of equipment by the same means, and with the same hardware.
When natural gas, propane or heating oil are burned in a furnace, the resulting hot combustion gasses by burning natural gas, propane or heating oil circulate through a heat exchanger. The heat exchanger will, in turn, release that heat to be circulated by the furnace’s blower. The flue gas then travels through the flue vent, which carries the gas outside of the home. When a heat exchanger is cracked, it generally will require a complete system replacement. That is one of the reasons why we highly recommend annual preventive maintenance on your home’s furnace – this preventative furnace inspection and maintenance can greatly prolong the life of your home heating system.
In 1758, Benjamin Franklin and John Hadley, a chemistry professor at Cambridge University, conducted an experiment to explore the principle of evaporation as a means to rapidly cool an object. Franklin and Hadley confirmed that evaporation of highly volatile liquids (such as alcohol and ether) could be used to drive down the temperature of an object past the freezing point of water. They conducted their experiment with the bulb of a mercury thermometer as their object and with a bellows used to speed up the evaporation. They lowered the temperature of the thermometer bulb down to −14 °C (7 °F) while the ambient temperature was 18 °C (64 °F). Franklin noted that, soon after they passed the freezing point of water 0 °C (32 °F), a thin film of ice formed on the surface of the thermometer's bulb and that the ice mass was about 6 mm (1⁄4 in) thick when they stopped the experiment upon reaching −14 °C (7 °F). Franklin concluded: "From this experiment one may see the possibility of freezing a man to death on a warm summer's day."[9]
So the furnace broke down (again). You may want to be talking to anyone but us right now, but in these circumstances, Roy Inch & Sons Service Experts Heating & Air Conditioning in London should be your very first call. You don’t even have to worry how late (or early) it is – our NATE-certified technicians are here for you 24/7/365. We’ll be there in a jiffy and get the job done fast – so you can get back to your life and not have to stress about needing another furnace repair anytime soon.
In the event of an emergency with your residential heating and cooling system, we understand that you simply cannot wait! At R.S. Andrews, we take your comfort and well-being seriously and are proud to offer our emergency HVAC repair at any hour, on any day—including weekends! We provide only the highest quality services to ensure your needs are met!
2Be sure the furnace’s circuit breaker is on or that its fuse has not blown. Check both the main electrical panel and any secondary subpanels that supply power to the unit. If the circuit has blown or tripped, reset the circuit breaker by flipping it all the way off and then on again. Or replace the fuse. If the circuit blows again, there is probably a short in the electrical system providing power to the furnace. For this, you may need to call an electrical contractor.
Yes. You should expect to pay a diagnostic fee to cover the cost of the technician's visit, the diagnosis of your air conditioner's problem, and a quote for the repair options. You will be advised of the issue along with recommended options to correct it, which may include a system replacement if your unit is old or significantly damaged. If you decide to replace the system, the diagnostic fee will be credited toward your replacement purchase.
Modern air conditioning systems are not designed to draw air into the room from the outside, they only recirculate the increasingly cool air on the inside. Because this inside air always has some amount of moisture suspended in it, the cooling portion of the process always causes ambient warm water vapor to condense on the cooling coils and to drip from them down onto a catch tray at the bottom of the unit from which it must then be routed outside, usually through a drain hole. As this moisture has no dissolved minerals in it, it will not cause mineral buildup on the coils. This will happen even if the ambient humidity level is low. If ice begins to form on the evaporative fins, it will reduce circulation efficiency and cause the development of more ice, etc. A clean and strong circulatory fan can help prevent this, as will raising the target cool temperature of the unit's thermostat to a point that the compressor is allowed to turn off occasionally. A failing thermistor may also cause this problem. Refrigerators without a defrost cycle may have this same issue. Dust can also cause the fins to begin blocking air flow with the same undesirable result: ice.

This review is for Ali, the service mechanic who responded to a service request at our home last week. We found Ali to be courteous, knowledgeable, and competent. This was not the first time Ali has been assigned to a serice call for us, and we are always pleased when he arrives. Ali not only takes the time to answer our questions, but often suggests ways to Increase the efficiency of our HVAC systems. He certainly represents Airtron well!!!
Please give us a call today at 1-800-948-MIKE (6453) for first-class air conditioning service and repairs in the Springfield, VA, Rockville, Silver Spring, MD & Washington D.C. metro area. We’re open seven days a week and provide 24/7 emergency service. For those who want to ensure that their AC unit is in working order before the summer season begins – or at any other time – we proudly offer a Heating & Cooling precision tune up to troubleshoot any potential AC problems. Upon completion of the AC inspection, we will provide you with a comprehensive written report regarding your Air Conditioning and Heating system’s status and make any recommendations necessary to improve your comfort level and head off any problems before they arise.
At Efficient Comfort, our mission is to provide our customers with the best in comfort, efficiency, and professionalism through honest work, fair pricing, and quality equipment.  Established in 2007, we continue to uphold the superior standards of job performance that protect your best interests.  Offering a full range of residential and commercial HVAC services in Broomfield, CO and surrounding areas, our NATE-certified technicians install, maintain, and repair all types of heating, cooling, air quality, and water heating units, ensuring peak condition and operation.
Locally owned and operated, our entire Dayton staff is ready to assist you the moment you call. You can expect the same service from the nearly 300 other One Hour Heating and Air Conditioning shops across the country. Being part of an organization as large as One Hour gives us leverage and backing with all the major brands such as Trane, Carrier, Lennox, Bryant, Honeywell, Goodman and Amana…and many more.  Being part of the One Hour Family allows us to stock our trucks like rolling warehouses carrying a large amount of parts and equipment so you don’t have to wait.  We also provide full service duct cleaning for you home or office.  Our professional staff will give you a free in home estimate and thoroughly explain the Duct Cleaning process.

Our air conditioner repair trucks are fully stocked with air conditioning repair parts and our highly trained air conditioning technicians and installation teams can repair or install a central air conditioning system right the first time. No job is too big or small; whether you need air conditioner repair work for a single unit or multiple units; you’ll get speedy, high-quality service that you can depend on. Our reliable service is the main reason so many consider us to be the best AC repair company in Houston TX! Call us now at 713-766-3605713-766-3605 to schedule an appointment.

Commercial HVAC systems are highly complex and extremely important for your commercial space. The team at Wm. Price Heating & Cooling has the knowledge and skills to ensure your heating and cooling units are operating at top efficiency and quality all year round. We have an extensive industry background and always adhere to strict standards for procedures, training, and customer service. We’re proud to offer advanced Carrier HVAC systems, so you know you’re getting the very best. Our NATE-certified technicians are always ready for all your commercial repair, service, and installation needs. Get in touch with our team today!
If you believe that the ac not working or you’re getting little or no cold air, check these three things first. Make sure all the registers in the house are wide open. Then be sure the furnace filter is clean. Then go outside and clean off the condenser coils (Photo 2). If several registers were closed or the filter was clogged, the reduced airflow could have caused the evaporator coil to ice up and stop cooling your home. If you’ve changed the filter and opened all the registers and you’re still not getting airflow at the registers, deice the A-coil. Move the thermostat mode switch from “Cooling” to “Off” and move the fan switch from “Auto” to “On.” Let the blower run for at least 30 minutes or until there’s good airflow at the registers. Then turn the AC back on to test it. If it works for the next 12 hours, you’ve solved the problem.

If you’re having trouble with your heating and air conditioning systems, give us a call now. With years of experience in the industry, we’re the right Spokane HVAC contractors for the job. Our team is capable of identifying any issues in your heating ventilation and cooling systems, and if it needs to be repaired or replaced, we’ll ensure that it’s done efficiently and at an affordable cost.
SEER is related to the coefficient of performance (COP) commonly used in thermodynamics and also to the Energy Efficiency Ratio (EER). The EER is the efficiency rating for the equipment at a particular pair of external and internal temperatures, while SEER is calculated over a whole range of external temperatures (i.e., the temperature distribution for the geographical location of the SEER test). SEER is unusual in that it is composed of an Imperial unit divided by an SI unit. The COP is a ratio with the same metric units of energy (joules) in both the numerator and denominator. They cancel out, leaving a dimensionless quantity. Formulas for the approximate conversion between SEER and EER or COP are available.[34]
Our technicians explain all of your options before beginning the repair, so you can decide whether a repair or replacement is best for you. Our No Surprises Pricing—including charging by the job, not by the hour—means the price we quote you is the price you pay. If you decide that replacing your furnace is the best course of action, we can install a new, high-efficiency model in its place.
×