During those frigid winter months, keeping your home warm is absolutely essential for your family’s health and well-being. An inefficient home heating system not only makes for an uncomfortable home life in the winter, it also drives up home heating costs. The past few years have yielded many advances in furnace and heating system technology, with manufacturers producing significantly more efficient equipment. A more energy efficient furnace or heating system keeps your home from losing heat which translates into visible savings on your heating bill. Whether you are looking for heating repair service or a complete overhaul of your home heating system and new heater installation, the HVAC technicians at Airtron keep everything Simple. Friendly. Direct.
Ground source, or geothermal, heat pumps are similar to ordinary heat pumps, but instead of transferring heat to or from outside air, they rely on the stable, even temperature of the earth to provide heating and air conditioning. Many regions experience seasonal temperature extremes, which would require large-capacity heating and cooling equipment to heat or cool buildings. For example, a conventional heat pump system used to heat a building in Montana's −70 °F (−57 °C) low temperature or cool a building in the highest temperature ever recorded in the US—134 °F (57 °C) in Death Valley, California, in 1913 would require a large amount of energy due to the extreme difference between inside and outside air temperatures. A few feet below the earth's surface, however, the ground remains at a relatively constant temperature. Utilizing this large source of relatively moderate temperature earth, a heating or cooling system's capacity can often be significantly reduced. Although ground temperatures vary according to latitude, at 6 feet (1.8 m) underground, temperatures generally only range from 45 to 75 °F (7 to 24 °C).

Clean air delivery rate is the amount of clean air an air cleaner provides to a room or space. When determining CADR, the amount of airflow in a space is taken into account. For example, an air cleaner with a flow rate of 100 cfm (cubic feet per minute) and an efficiency of 50% has a CADR of 50 cfm. Along with CADR, filtration performance is very important when it comes to the air in our indoor environment. Filter performance depends on the size of the particle or fiber, the filter packing density and depth and also the air flow rate.[28]
Should you need to replace an air conditioning unit, Abacus Plumbing recommends Lennox brand of air conditioning and heating systems. Lennox systems offer the highest level of home comfort at the lowest possible cost of operation. Additionally, these systems are praised by consumer publications and meet or exceed all government standards for efficiency. Learn more about installation »
The performance of vapor compression refrigeration cycles[24] is limited by thermodynamics. These air conditioning and heat pump devices move heat rather than convert it from one form to another, so thermal efficiencies do not appropriately describe the performance of these devices. The Coefficient-of-Performance (COP) measures performance, but this dimensionless measure has not been adopted. Instead, the Energy Efficiency Ratio (EER) has traditionally been used to characterize the performance of many HVAC systems. EER is the Energy Efficiency Ratio based on a 35 °C (95 °F) outdoor temperature. To more accurately describe the performance of air conditioning equipment over a typical cooling season a modified version of the EER, the Seasonal Energy Efficiency Ratio (SEER), or in Europe the ESEER, is used. SEER ratings are based on seasonal temperature averages instead of a constant 35 °C (95 °F) outdoor temperature. The current industry minimum SEER rating is 14 SEER.[25]
The fan limit switch controls the furnace blower. The fan limit switch has three settings: “Fan On”, “Fan Off”, and “Limit”. In the “Fan Off” setting, the blower will only operate if there is warm air in the plenum to prevent cool air from blowing into the home. The “Fan On” setting will keep the blower operating even after the burner has shutdown, making sure that all of the hot air produced is circulated. The “Limit” setting is a safety control that will turn the burner off in the rare event that the air in the warm air plenum reaches an unsafe temperature. This may be the case if ducts are blocked or if the system controls are malfunctioning.
R22 (also known as HCFC-22) has a global warming potential about 1,800 times higher than CO2.[61] It was phased out for use in new equipment by 2010, and is to be completely discontinued by 2020. Although these gasses can be recycled when air conditioning units are disposed of, uncontrolled dumping and leaking can release gas directly into the atmosphere.
In 1995, Germany made CFC refrigerators illegal.[22] DuPont and other companies blocked the refrigerant in the U.S. with the U.S. EPA, disparaging the approach as "that German technology".[21][23] Nevertheless, in 2004, Greenpeace worked with multinational corporations like Coca-Cola and Unilever, and later Pepsico and others, to create a corporate coalition called Refrigerants Naturally!.[22][24] Then, four years later, Ben & Jerry's of Unilever and General Electric began to take steps to support production and use in the U.S.[25] In 2011 the EPA decided in favor of the ozone- and climate-safe refrigerant for U.S. manufacture.[17][26][27]
In a thermodynamically closed system, any power dissipated into the system that is being maintained at a set temperature (which is a standard mode of operation for modern air conditioners) requires that the rate of energy removal by the air conditioner increase. This increase has the effect that, for each unit of energy input into the system (say to power a light bulb in the closed system), the air conditioner removes that energy.[30] To do so, the air conditioner must increase its power consumption by the inverse of its "efficiency" (coefficient of performance) times the amount of power dissipated into the system. As an example, assume that inside the closed system a 100 W heating element is activated, and the air conditioner has a coefficient of performance of 200%. The air conditioner's power consumption will increase by 50 W to compensate for this, thus making the 100 W heating element cost a total of 150 W of power.
In the refrigeration cycle, heat is transported from a colder location to a hotter area. As heat would naturally flow in the opposite direction, work is required to achieve this. A refrigerator is an example of such a system, as it transports the heat out of the interior and into its environment. The refrigerant is used as the medium which absorbs and removes heat from the space to be cooled and subsequently ejects that heat elsewhere.
This information is not intended as an offer to sell, or the solicitation of an offer to buy, a franchise. It is for information purposes only. Read More Currently, the following states regulate the offer and sale of franchises: California, Hawaii, Illinois, Indiana, Maryland, Michigan, Minnesota, New York, North Dakota, Oregon, Rhode Island, South Dakota, Virginia, Washington, and Wisconsin. If you are a resident of or want to locate a franchise in one of these states, we will not offer you a franchise unless and until we have complied with applicable pre-sale registration and disclosure requirements in your state. Read Less Aire Serv is a registered trademark of Aire Serv LLC © Aire Serv | All rights reserved | All Aire Serv franchise locations are independently owned and operated.
Air ducts come in two forms: cool air ducts (also known as “return ducts”) and warm air ducts (also known as “supply ducts”). Warm air from the furnace enters the home through the warm air registers. No more than 20: of these warm air ducts and registers should ever be closed off – this hinders air flow and could result in the overheating of the heat exchanger, causing costly damage to you home heating system.
The chill of winter can be a scary thought when your furnace needs repair. When the furnace in your home goes on the fritz, you need it fixed right away to keep your family safe and comfortable. Every BGE HOME technician is licensed and adheres to a stringent in-house certification program that guarantees their knowledge, affirms their commitment to the customer, and ensures excellence in completing every furnace repair with the highest level of quality.
×