Because an air conditioner moves heat between the indoor coil and the outdoor coil, both must be kept clean. This means that, in addition to replacing the air filter at the evaporator coil, it is also necessary to regularly clean the condenser coil. Failure to keep the condenser clean will eventually result in harm to the compressor, because the condenser coil is responsible for discharging both the indoor heat (as picked up by the evaporator) and the heat generated by the electric motor driving the compressor.
Modern refrigerants have been developed to be more environmentally safe than many of the early chlorofluorocarbon-based refrigerants used in the early- and mid-twentieth century. These include HCFCs (R-22, as used in most U.S. homes before 2011) and HFCs (R-134a, used in most cars) have replaced most CFC use. HCFCs, in turn, are supposed to have been in the process of being phased out under the Montreal Protocol and replaced by HFCs such as R-410A, which lack chlorine.[14] HFCs, however, contribute to climate change problems. Moreover, policy and political influence by corporate executives resisted change.[15][16] Corporations insisted that no alternatives to HFCs existed. The environmental organization Greenpeace provided funding to a former East German refrigerator company to research an alternative ozone- and climate-safe refrigerant in 1992. The company developed a hydrocarbon mix of isopentane and isobutane, but as a condition of the contract with Greenpeace could not patent the technology, which led to its widespread adoption by other firms.[17][18][19] Their activist marketing first in Germany led to companies like Whirlpool, Bosch, and later LG and others to incorporate the technology throughout Europe, then Asia, although the corporate executives resisted in Latin America, so that it arrived in Argentina produced by a domestic firm in 2003, and then finally with giant Bosch's production in Brazil by 2004.[20][21]
James Harrison's first mechanical ice-making machine began operation in 1851 on the banks of the Barwon River at Rocky Point in Geelong, Australia. His first commercial ice-making machine followed in 1853, and his patent for an ether vapor compression refrigeration system was granted in 1855. This novel system used a compressor to force the refrigeration gas to pass through a condenser, where it cooled down and liquefied. The liquefied gas then circulated through the refrigeration coils and vaporized again, cooling down the surrounding system. The machine produced 3,000 kilograms (6,600 lb) of ice per day.[citation needed]

An example of a geothermal heat pump that uses a body of water as the heat sink, is the system used by the Trump International Hotel and Tower in Chicago, Illinois. This building is situated on the Chicago River, and uses cold river water by pumping it into a recirculating cooling system, where heat exchangers transfer heat from the building into the water, and then the now-warmed water is pumped back into the Chicago River.[22]
Dichlorodifluoromethane (R-12) was the most common blend used in automobiles in the U.S. until 1994, when most designs changed to R-134A due to the ozone-depleting potential of R-12. R-11 and R-12 are no longer manufactured in the U.S. for this type of application, so the only source for air-conditioning repair purposes is the cleaned and purified gas recovered from other air conditioner systems. Several non-ozone-depleting refrigerants have been developed as alternatives, including R-410A. It was first commercially used by Carrier Corp. under the brand name Puron.[citation needed]
In order to make your everyday life easier and more enjoyable, Sky Heating & Air Conditioning specializes in state-of-the-art heating and cooling technology, partnering with Trane, Mitsubishi, and Waterfurnace.  We bring you HVAC solutions that represent the best the industry has to offer, ensuring long-term performance and satisfaction.  Whether you’re looking for the design/build of a new system, replacement, or hoping to cut costs and enhance convenience, we answer with proven products.  Our qualified HVAC technicians help you determine the ideal solution for your exact requirements, and make sure you’re happy with every step of the process.  From ductless HVAC to geothermal heating and cooling systems, we offer a wide selection of options and comprehensive services to answer any type of challenge.  Call on Sky Heating & Air Conditioning and let us exceed your expectations today!
It’s important to keep your furnace receives regular maintenance to ensure that it’s working properly and efficiently. Routine maintenance can also extend the life of your heating system by several years. Ask about our annual maintenance agreements that cover your plumbing, heating, and cooling systems and save you money. A furnace that has been neglected may be working too hard, which can result in inconsistent air temperatures in your Minneapolis area home. Learn more about the importance of routine maintenance on your HVAC system.
Problems donating? | Other ways to give | Frequently asked questions | We never sell your information. By submitting, you are agreeing to our donor privacy policy. The Wikimedia Foundation is a nonprofit, tax-exempt organization. If you make a recurring donation, you will be debited by the Wikimedia Foundation until you notify us to stop. We'll send you an email receipt for each payment, which will include a link to easy cancellation instructions.

PSNC Energy appliance sales, installation, maintenance, and repair are not a part of the regulated services offered by PSNC Energy and are not in any way sanctioned by the North Carolina Utilities Commission. There is no advantage to customers of PSNC Energy if they buy these products or services from PSNC Energy. A customer does not have to buy such products or services in order to continue to receive the same safe and reliable natural gas service from PSNC Energy.


Refrigeration air conditioning equipment usually reduces the absolute humidity of the air processed by the system. The relatively cold (below the dewpoint) evaporator coil condenses water vapor from the processed air, much like an ice-cold drink will condense water on the outside of a glass. Therefore, water vapor is removed from the cooled air and the relative humidity in the room is lowered. The water is usually sent to a drain or may simply drip onto the ground outdoors. The heat is rejected by the condenser which is located outside of room to be cooled.


The three major functions of heating, ventilation, and air conditioning are interrelated, especially with the need to provide thermal comfort and acceptable indoor air quality within reasonable installation, operation, and maintenance costs. HVAC systems can be used in both domestic and commercial environments. HVAC systems can provide ventilation, and maintain pressure relationships between spaces. The means of air delivery and removal from spaces is known as room air distribution.[3]
For regular upkeep, Bay Area Air Conditioning, Inc. draws from 43 years of practical experience.  We’ve learned that an intense Higher Performance Tune Up and Cleaning effectively restores the capacity, efficiency, sound levels, and overall performance of all makes and models of HVAC equipment to peak condition.  Should you experience a problem, we offer free second options, cost-effective recommendations, and prompt repairs.  We stand behind all new installation projects with our ten year parts and labor warranty, and verify performance data to ensure quality of operation. We aim to be the best HVAC company in Crystal River, FL and Central Florida.

Furnaces and thermostats are not mix-and-match appliances. Using the wrong type of thermostat with a furnace will cause operating problems and can be dangerous. Although thermostats look similar, they are designed very differently. There are numerous types of heating systems and thermostat systems and they need to be coordinated for safe and proper operation. There are three types of thermostat systems used today: millivoltage, low voltage, and line voltage.​
×