The selection of indoor units has one restriction: their total power should not exceed the capacity of the outdoor unit. In practice, however, it is very common to see a multi-split system with a total capacity of indoor units greater than the outdoor capacity by at least 20%. However, it is wrong to expect better performance when all indoor units are turned on at the same time, since the total capacity of the whole system is limited by the capacity of the outdoor unit. Simply put, the outdoor unit will distribute all its power to all operating indoor units in such a way that some of the rooms may not have a very comfortable temperature level. However, the calculation of the total power is not simple, since it takes into account not only the nominal power of the units, but also the cooling capacity, heating, dehumidification, humidification, venting, etc.


The belt should slip right into place. If it seems to be too tight or difficult to set in place, it may be necessary to adjust the motor mount to provide more slack. Then you can re-tighten the tension once the belt is in place. Check the manufacturer’s specifications for proper tension—in most cases, the belt should deflect about an inch when you press down on it.
SEER is related to the coefficient of performance (COP) commonly used in thermodynamics and also to the Energy Efficiency Ratio (EER). The EER is the efficiency rating for the equipment at a particular pair of external and internal temperatures, while SEER is calculated over a whole range of external temperatures (i.e., the temperature distribution for the geographical location of the SEER test). SEER is unusual in that it is composed of an Imperial unit divided by an SI unit. The COP is a ratio with the same metric units of energy (joules) in both the numerator and denominator. They cancel out, leaving a dimensionless quantity. Formulas for the approximate conversion between SEER and EER or COP are available.[34]
2Be sure the furnace’s circuit breaker is on or that its fuse has not blown. Check both the main electrical panel and any secondary subpanels that supply power to the unit. If the circuit has blown or tripped, reset the circuit breaker by flipping it all the way off and then on again. Or replace the fuse. If the circuit blows again, there is probably a short in the electrical system providing power to the furnace. For this, you may need to call an electrical contractor.
If you’re having trouble with your heating and air conditioning systems, give us a call now. With years of experience in the industry, we’re the right Spokane HVAC contractors for the job. Our team is capable of identifying any issues in your heating ventilation and cooling systems, and if it needs to be repaired or replaced, we’ll ensure that it’s done efficiently and at an affordable cost.
If you believe that the ac not working or you’re getting little or no cold air, check these three things first. Make sure all the registers in the house are wide open. Then be sure the furnace filter is clean. Then go outside and clean off the condenser coils (Photo 2). If several registers were closed or the filter was clogged, the reduced airflow could have caused the evaporator coil to ice up and stop cooling your home. If you’ve changed the filter and opened all the registers and you’re still not getting airflow at the registers, deice the A-coil. Move the thermostat mode switch from “Cooling” to “Off” and move the fan switch from “Auto” to “On.” Let the blower run for at least 30 minutes or until there’s good airflow at the registers. Then turn the AC back on to test it. If it works for the next 12 hours, you’ve solved the problem.
Air-source heat pumps are more popular in milder winter climates where the temperature is frequently in the range of 4–13 °C (40–55 °F), because heat pumps become inefficient in more extreme cold. This is because ice forms on the outdoor unit's heat exchanger coil, which blocks air flow over the coil. To compensate for this, the heat pump system must temporarily switch back into the regular air conditioning mode to switch the outdoor evaporator coil back to being the condenser coil, so that it can heat up and defrost. A heat pump system will therefore have a form of electric resistance heating in the indoor air path that is activated only in this mode in order to compensate for the temporary indoor air cooling, which would otherwise be uncomfortable in the winter.
Air conditioners can create a lot of water because they remove moisture from the air. To get rid of this, they have a [usually plastic] drain pipe that comes out of the side of the air handler. Over time, algae can block this pipe and, when it does, the AC won’t work. In fact, some condensate drains have a float switch that won’t let the AC run if water backs-up. Water can also puddle around the unit or flood the area. To deal with condensate problems, please see Air Conditioner Leaks Water, below.
Response time was incredibly fast! The problem with the air conditioner was fully explained to me and was corrected. It was suggested that I buy a maintenance plan, which I did. I wouldn’t hesitate to recommend Roussos Air Conditioning for their quality service, friendly and knowledgeable technicians. Their customer service rep answering the phone who was so helpful when I called. I wouldn't dream of calling anyone else in the future.
Geothermal Heating and Cooling systems are unmatched in every way. This green alternative to temperature control is three times more efficient than conventional systems. Recognized by the US Environmental Protection Agency as the most environmentally-friendly option available today, installation of a geothermal HVAC system translates into a 50% reduction in heating costs, 30% reduction in cooling costs, and a 65% potential savings on hot water costs.  Sky Heating & Air Conditioning is now the largest WaterFurnace geothermal contractor west of Iowa. Our team of experienced professionals offer conscientious and skilled start-to-finish installation and service.  We specialize in outstanding geothermal HVAC systems, adding value and enjoyment to your home through sustainable solutions to year round temperature control. Contact Sky Heating & Air Conditioning for geothermal heat pump installation in Portland.

Sky Heating & Air Conditioning provides a wide range of quality HVAC services to homeowners across Portland and The Dalles.  By bringing together skilled technicians and premier products, we deliver superior value for your investment.  We utilize tried and true strategies to enhance efficiency, comfort, and convenience throughout your home.  For heating and air conditioning installation, repair, and regular maintenance, no one takes better care of you than Sky Heating & Air Conditioning.  And we’re always here!  Count on us 24 hours a day, 7 days a week, to protect your safety, comfort, and best interests.
It’s important to keep your furnace receives regular maintenance to ensure that it’s working properly and efficiently. Routine maintenance can also extend the life of your heating system by several years. Ask about our annual maintenance agreements that cover your plumbing, heating, and cooling systems and save you money. A furnace that has been neglected may be working too hard, which can result in inconsistent air temperatures in your Minneapolis area home. Learn more about the importance of routine maintenance on your HVAC system.
High-efficiency condensing furnaces (90% AFUE and above) are a bit more complex than conventional furnaces. The main differences between a conventional and condensing furnace are the heat exchanger technology used to extract heat from the combustion process and the method used to exhaust the combustion gases. In these ways, the furnaces are very different. The condensing furnace does not have a significantly more efficient combustion process than does a conventional furnace; both use gas burners with electronic ignition. The difference lies in that the condensing furnace has a more efficient heat extraction process after combustion.
×