If your home is not heated using forced air, chances are a boiler will make sure you stay warm during cold nights. A hot water system delivers hot water through a network of pipes that run to every room in your house. The heating effect gets maximized through radiators. The most common issues with hot water heating tend to be not be major, but small problems that add up over time. Mineral deposits within the water tank, a pilot light malfunction, or an issue with a radiator itself can require professional repair. On average, you will pay between $183 and $582 for these problems. The exact amount will depend on the exact problem, as described in our boiler repair cost guide.
If you have an older central air conditioner, you might choose to replace the outdoor compressor with a modern, high-efficiency unit. If you do so, consult a local heating and cooling contractor to assure that the new compressor is properly matched to the indoor unit. However, considering recent changes in refrigerants and air conditioning designs, it might be wiser to replace the entire system.

When you work with Bob’s, we make sure your furnace is properly sized and installed for optimal performance. When it comes to furnace installation in Renton, WA, Bob’s is dedicated to excellence, which defines our service. We know that professional furnace installation is the best way to protect its performance quality. Call today for more details.


Our technicians explain all of your options before beginning the repair, so you can decide whether a repair or replacement is best for you. Our No Surprises Pricing—including charging by the job, not by the hour—means the price we quote you is the price you pay. If you decide that replacing your furnace is the best course of action, we can install a new, high-efficiency model in its place.

A specialized air conditioner that is used only for dehumidifying is called a dehumidifier. It also uses a refrigeration cycle, but differs from a standard air conditioner in that both the evaporator and the condenser are placed in the same air path. A standard air conditioner transfers heat energy out of the room because its condenser coil releases heat outside. However, since all components of the dehumidifier are in the same room, no heat energy is removed. Instead, the electric power consumed by the dehumidifier remains in the room as heat, so the room is actually heated, just as by an electric heater that draws the same amount of power.

Turn off the gas supply valve, typically located by your gas meter on the gas inlet pipe. Turn off the gas by rotating the valve one quarter turn with an adjustable wrench. When the gas is off,  the valve’s oblong stem points perpendicular to the inlet pipe. Then call your gas utility or the fire department from a remote location. Do not return to your home until you know it is safe.


It's a little awkward, so we'll get straight to the point: This Wednesday we humbly ask you to defend Wikipedia's independence. We depend on donations averaging about $16.36. But 98% of our readers in the U.S. are not responding to our messages, and time is running out to help in 2018. If everyone reading this gave $2.75, we could keep Wikipedia thriving for years to come. The price of your Wednesday coffee is all we need. When we made Wikipedia a non-profit, people warned us we'd regret it. But if Wikipedia were commercial, it would be a great loss. Wikipedia unites all of us who love knowledge: contributors, readers and the donors who keep us thriving. The heart and soul of Wikipedia is a community of people working to bring you unlimited access to reliable information. Please take a minute to help us keep Wikipedia growing. Thank you.
As a Kansas City Heating and Cooling company, Anthony’s professional technicians are not only friendly, but extremely skilled. No matter what the problem with your air conditioner or furnace is, they can solve it. But don’t wait until there is a problem. Enroll in our annual service program and we’ll keep all your equipment maintained so you get the most out of your furnace, air conditioner, and plumbing equipment. An ounce of prevention is worth a pound of cure, so our service program pays for itself.
Beware these aluminum clad wood doors. The wood is particle board. Why would anyone make a storm door out of particle board? They don't seal it in any way, it gets wet between the aluminum cladding and boils and blisters the aluminum and looks terrible in just a few years. I have two Larson's and they were horrible doors almost from the start. I've seen reviews and EMCO is the exact same way. When your storm door needs a storm door, you bought the wrong door.
“I had the pleasure of meeting CJ. He was a lifesaver for our family. First snow of the year and our heater had an issue. He was able to show up within 15 minutes and diagnos the problem. He even lent us a space heater for the time being; as we had to wait for a part. Once the part was available he was prompt to arrive and fix it in no time. Thank you so much CJ! Just in time for family to arrive. I will be a life long customer.”
The condensed, pressurized, and still usually somewhat hot liquid refrigerant is next routed through an expansion valve (often nothing more than a pinhole in the system's copper tubing) where it undergoes an abrupt reduction in pressure. That pressure reduction results in flash evaporation of a part of the liquid refrigerant, greatly lowering its temperature. The cold refrigerant is then routed through the evaporator. A fan blows the interior warm air (which is to be cooled) across the evaporator, causing the liquid part of the cold refrigerant mixture to evaporate as well, further lowering the temperature. The warm air is therefore cooled and is pumped by an exhaust fan/ blower into the room. To complete the refrigeration cycle, the refrigerant vapor is routed back into the compressor. In order for the process to have any efficiency, the cooling/evaporative portion of the system must be separated by some kind of physical barrier from the heating/condensing portion, and each portion must have its own fan to circulate its own "kind" of air (either the hot air or the cool air).
The basic concept behind air conditioning is said to have been applied in ancient Egypt, where reeds were hung in windows and were moistened with trickling water. The evaporation of water cooled the air blowing through the window. This process also made the air more humid, which can be beneficial in a dry desert climate. In ancient Rome, water from aqueducts was circulated through the walls of certain houses to cool them. Other techniques in medieval Persia involved the use of cisterns and wind towers to cool buildings during the hot season.[5]
Replacing a capacitor is easy. Just take a photo of the wires before disconnecting anything (you may need a reference later on). Then discharge the stored energy in the old capacitor (Photo 4). Use needle-nose pliers to pluck one wire at a time from the old capacitor and snap it onto the corresponding tab of the new capacitor. The female crimp connectors should snap tightly onto the capacitor tabs. Wiggle each connector to see if it’s tight. If it’s not, remove the connector and bend the rounded edges of it so it makes a tighter fit on the tab. When you’ve swapped all the wires, secure the new capacitor (Photo 5).

Air flow meter Aquastat BACnet Blower door Building automation Carbon dioxide sensor Clean Air Delivery Rate (CADR) Gas sensor Home energy monitor Humidistat HVAC control system Intelligent buildings LonWorks Minimum efficiency reporting value (MERV) OpenTherm Programmable communicating thermostat Programmable thermostat Psychrometrics Room temperature Smart thermostat Thermostat Thermostatic radiator valve
As touched on by their name, heat pumps function by transferring heat energy indoors during the winter and outdoors from your home during the summer. They're often attached to air conditioning units, using the surrounding air to transfer energy. However, geothermal heat pumps and water source heat pumps are also available. The cost to repair a heat pump, again, depends on the specific problem. Replacing a faulty thermostat may cost up to $300 including labor, while a worn or damaged defrost control board can set you back up to $600. For more details on your potential repair costs using this heating source, visit our heat pump repair cost guide.

In 1906, Stuart W. Cramer of Charlotte was exploring ways to add moisture to the air in his textile mill. Cramer coined the term "air conditioning", using it in a patent claim he filed that year as an analogue to "water conditioning", then a well-known process for making textiles easier to process. He combined moisture with ventilation to "condition" and change the air in the factories, controlling the humidity so necessary in textile plants. Willis Carrier adopted the term and incorporated it into the name of his company.[10]
In the refrigeration cycle, heat is transported from a colder location to a hotter area. As heat would naturally flow in the opposite direction, work is required to achieve this. A refrigerator is an example of such a system, as it transports the heat out of the interior and into its environment. The refrigerant is used as the medium which absorbs and removes heat from the space to be cooled and subsequently ejects that heat elsewhere.
A specialized air conditioner that is used only for dehumidifying is called a dehumidifier. It also uses a refrigeration cycle, but differs from a standard air conditioner in that both the evaporator and the condenser are placed in the same air path. A standard air conditioner transfers heat energy out of the room because its condenser coil releases heat outside. However, since all components of the dehumidifier are in the same room, no heat energy is removed. Instead, the electric power consumed by the dehumidifier remains in the room as heat, so the room is actually heated, just as by an electric heater that draws the same amount of power.

In the case of heated water or steam, piping is used to transport the heat to the rooms. Most modern hot water boiler heating systems have a circulator, which is a pump, to move hot water through the distribution system (as opposed to older gravity-fed systems). The heat can be transferred to the surrounding air using radiators, hot water coils (hydro-air), or other heat exchangers. The radiators may be mounted on walls or installed within the floor to produce floor heat.
A specialized air conditioner that is used only for dehumidifying is called a dehumidifier. It also uses a refrigeration cycle, but differs from a standard air conditioner in that both the evaporator and the condenser are placed in the same air path. A standard air conditioner transfers heat energy out of the room because its condenser coil releases heat outside. However, since all components of the dehumidifier are in the same room, no heat energy is removed. Instead, the electric power consumed by the dehumidifier remains in the room as heat, so the room is actually heated, just as by an electric heater that draws the same amount of power.
American design standards are legislated in the Uniform Mechanical Code or International Mechanical Code. In certain states, counties, or cities, either of these codes may be adopted and amended via various legislative processes. These codes are updated and published by the International Association of Plumbing and Mechanical Officials (IAPMO) or the International Code Council (ICC) respectively, on a 3-year code development cycle. Typically, local building permit departments are charged with enforcement of these standards on private and certain public properties.
If you hear clicking that is followed by a hum or buzz, you’re probably hearing the fan motor attempting to start without the boost it needs from the capacitor. You can almost always conclude that the capacitor has failed. Sometimes you can get the compressor fan spinning (clockwise) by pushing it with a thin stick or long screwdriver poked through the grille. But the chances are good that this might work for one cycle, but the capacitor will fail next time the AC goes on. It’s best to replace the capacitor.
Before calling to schedule your appointment, it may be helpful to familiarize yourself with the air conditioning equipment that you have. Make sure you know at least the brand name, the model and the approximate age of the system, as well as any warranties that may be in effect—and read through our AC FAQ to see if any of your symptoms sound familiar.
Excalibur Water Systems helps solve the water challenges around the globe with water solutions for any possible water concerns in: water hardness, filtration of any contaminant, bacteria removal and high purity water needs and also comes with a warranty of up to 20 years at no extra cost. The best warranty for the water treatment equipment industry.
Our partner, Goodman Air Conditioning and Heating, is a leading HVAC manufacturer. Their products deliver outstanding comfort with the money-saving efficiency ratings that every homeowner deserves. From the first HVAC diagnostic and inspection to every maintenance test, we ensure that our systems are durable and provide lasting quality to your day-to-day life.

Modern air conditioning systems are not designed to draw air into the room from the outside, they only recirculate the increasingly cool air on the inside. Because this inside air always has some amount of moisture suspended in it, the cooling portion of the process always causes ambient warm water vapor to condense on the cooling coils and to drip from them down onto a catch tray at the bottom of the unit from which it must then be routed outside, usually through a drain hole. As this moisture has no dissolved minerals in it, it will not cause mineral buildup on the coils. This will happen even if the ambient humidity level is low. If ice begins to form on the evaporative fins, it will reduce circulation efficiency and cause the development of more ice, etc. A clean and strong circulatory fan can help prevent this, as will raising the target cool temperature of the unit's thermostat to a point that the compressor is allowed to turn off occasionally. A failing thermistor may also cause this problem. Refrigerators without a defrost cycle may have this same issue. Dust can also cause the fins to begin blocking air flow with the same undesirable result: ice.
If your compressor doesn’t have an overload button and you hear it humming or buzzing, poke a screwdriver or stick down through the top grille and try to spin the fan blades clockwise. If doing this gives the fan enough of a boost to get it going, the unit has a faulty capacitor that must be replaced. See How to Test and Replace an AC Run Capacitor, above.

In the event of an emergency with your residential heating and cooling system, we understand that you simply cannot wait! At R.S. Andrews, we take your comfort and well-being seriously and are proud to offer our emergency HVAC repair at any hour, on any day—including weekends! We provide only the highest quality services to ensure your needs are met!


Since the 1980s, manufacturers of HVAC equipment have been making an effort to make the systems they manufacture more efficient. This was originally driven by rising energy costs, and has more recently been driven by increased awareness of environmental issues. Additionally, improvements to the HVAC system efficiency can also help increase occupant health and productivity.[21] In the US, the EPA has imposed tighter restrictions over the years. There are several methods for making HVAC systems more efficient.
Our partner, Goodman Air Conditioning and Heating, is a leading HVAC manufacturer. Their products deliver outstanding comfort with the money-saving efficiency ratings that every homeowner deserves. From the first HVAC diagnostic and inspection to every maintenance test, we ensure that our systems are durable and provide lasting quality to your day-to-day life.
Energy efficiency can be improved even more in central heating systems by introducing zoned heating. This allows a more granular application of heat, similar to non-central heating systems. Zones are controlled by multiple thermostats. In water heating systems the thermostats control zone valves, and in forced air systems they control zone dampers inside the vents which selectively block the flow of air. In this case, the control system is very critical to maintaining a proper temperature.
what should be the length of the drain vent. I had it at the roof level. But since I am getting bad smell in my house via bathrooms (or may be via roof door), I have just extended the length of the vent pipe. Is there any scientific method to estimate the right length? Plus is there any tester to test from where the bad sewage odor is coming from into the living room. It's a two-story villa.

If you need an experienced Westminster furnace repair and installation expert please call Brothers Plumbing & Heating today. Our policy is to make our Westminster furnace repair customers happy today or they don’t pay. We are experienced HVAC contractors who have been providing heating service in Westminster for over 30 years. When it’s freezing outside, a heating outage can be an emergency especially for the sick or elderly. That is why we provide fast Westminster furnace repair.

We provide plumbing service to Atlanta and the surrounding communities, including: Acworth, Alpharetta, Austell, Avondale Estates, Brookhaven, Buford, Chamblee, Clarkston, Conyers, Cumming, Dacula, Decatur, Doraville, Douglasville, Duluth, Dunwoody, Fayetteville, Forest Park, Grayson, Holly Springs, Johns Creek, Kennesaw, Lawrenceville, Lilburn, Lithonia, Loganville, Marietta, Milton, Morrow, Norcross, Peach Tree City, Pine Lake, Powder Springs, Roswell, Sandy Springs, Snellville, Stone Mountain, Sugar Hill, Suwanee, and Woodstock, GA.
If you want to avoid major renovations, have a space without the necessary ductwork, or simply want a cost-efficient, simple alternative to cumbersome heating and cooling units, consider a ductless HVAC system from Wm. Price Heating & Cooling! Innovative ductless systems are great for home additions, new construction, condominiums, apartments, or to target temperature control in certain rooms. You’ll have the ability to adjust temperatures for specific zones of the home while also enjoying a non-invasive unit. Ductless HVAC systems are more environmentally responsible, quicker to install, and less wasteful than systems that use ductwork. Get in touch with our team today to learn more about our ductless HVAC services!

The fan limit switch controls the furnace blower. The fan limit switch has three settings: “Fan On”, “Fan Off”, and “Limit”. In the “Fan Off” setting, the blower will only operate if there is warm air in the plenum to prevent cool air from blowing into the home. The “Fan On” setting will keep the blower operating even after the burner has shutdown, making sure that all of the hot air produced is circulated. The “Limit” setting is a safety control that will turn the burner off in the rare event that the air in the warm air plenum reaches an unsafe temperature. This may be the case if ducts are blocked or if the system controls are malfunctioning.

If you believe that the ac not working or you’re getting little or no cold air, check these three things first. Make sure all the registers in the house are wide open. Then be sure the furnace filter is clean. Then go outside and clean off the condenser coils (Photo 2). If several registers were closed or the filter was clogged, the reduced airflow could have caused the evaporator coil to ice up and stop cooling your home. If you’ve changed the filter and opened all the registers and you’re still not getting airflow at the registers, deice the A-coil. Move the thermostat mode switch from “Cooling” to “Off” and move the fan switch from “Auto” to “On.” Let the blower run for at least 30 minutes or until there’s good airflow at the registers. Then turn the AC back on to test it. If it works for the next 12 hours, you’ve solved the problem.
Furnaces and thermostats are not mix-and-match appliances. Using the wrong type of thermostat with a furnace will cause operating problems and can be dangerous. Although thermostats look similar, they are designed very differently. There are numerous types of heating systems and thermostat systems and they need to be coordinated for safe and proper operation. There are three types of thermostat systems used today: millivoltage, low voltage, and line voltage.​
×