Central home air conditioner service systems consist of two major components: a condensing unit that sits outside your house, and the evaporator coil (often referred to as an A-coil) that sits in the plenum of your furnace or air handler. The refrigerant in the A-coil picks up the heat from your home and moves it to the outdoor condensing unit. The condensing unit fan blows outside air through the condensing coil to remove the heat. The condensing unit houses the three parts replaceable by a DIYer: the contactor, the start/run capacitor(s) and the condenser fan motor. The condensing unit also houses the compressor, but only a pro can replace that. The A-coil has no parts that can be serviced by a DIYer.
Clean air delivery rate is the amount of clean air an air cleaner provides to a room or space. When determining CADR, the amount of airflow in a space is taken into account. For example, an air cleaner with a flow rate of 100 cfm (cubic feet per minute) and an efficiency of 50% has a CADR of 50 cfm. Along with CADR, filtration performance is very important when it comes to the air in our indoor environment. Filter performance depends on the size of the particle or fiber, the filter packing density and depth and also the air flow rate.[28]
A dehumidifier is an air-conditioner-like device that controls the humidity of a room or building. It is often employed in basements which have a higher relative humidity because of their lower temperature (and propensity for damp floors and walls). In food retailing establishments, large open chiller cabinets are highly effective at dehumidifying the internal air. Conversely, a humidifier increases the humidity of a building.
Answering the severe weather swings of the Brownsville, Connellsville, Masontown, Perryopolis, Smithfield & Uniontown, PA area, we bring our customers the most sophisticated and economical solutions to home temperature control. We remain dedicated, not only to the complete satisfaction of local homeowners and businesses, but also to providing environmentally responsible options.
Air conditioners can create a lot of water because they remove moisture from the air. To get rid of this, they have a [usually plastic] drain pipe that comes out of the side of the air handler. Over time, algae can block this pipe and, when it does, the AC won’t work. In fact, some condensate drains have a float switch that won’t let the AC run if water backs-up. Water can also puddle around the unit or flood the area. To deal with condensate problems, please see Air Conditioner Leaks Water, below.
Hospital operating theatres, in which air is filtered to high levels to reduce infection risk and the humidity controlled to limit patient dehydration. Although temperatures are often in the comfort range, some specialist procedures, such as open heart surgery, require low temperatures (about 18 °C, 64 °F) and others, such as neonatal, relatively high temperatures (about 28 °C, 82 °F).
“I had the pleasure of meeting CJ. He was a lifesaver for our family. First snow of the year and our heater had an issue. He was able to show up within 15 minutes and diagnos the problem. He even lent us a space heater for the time being; as we had to wait for a part. Once the part was available he was prompt to arrive and fix it in no time. Thank you so much CJ! Just in time for family to arrive. I will be a life long customer.”
As touched on by their name, heat pumps function by transferring heat energy indoors during the winter and outdoors from your home during the summer. They're often attached to air conditioning units, using the surrounding air to transfer energy. However, geothermal heat pumps and water source heat pumps are also available. The cost to repair a heat pump, again, depends on the specific problem. Replacing a faulty thermostat may cost up to $300 including labor, while a worn or damaged defrost control board can set you back up to $600. For more details on your potential repair costs using this heating source, visit our heat pump repair cost guide.
Most modern air-conditioning systems feature a dehumidification cycle during which the compressor runs while the fan is slowed as much as possible[citation needed] to reduce the evaporator temperature and therefore condense more water. When the temperature falls below a threshold, both the fan and compressor are shut off to mitigate further temperature drops;[clarification needed] this prevents moisture on the evaporator from being blown back into the room.[citation needed] When the temperature rises again,[clarification needed] the compressor restarts and the fan returns to low speed.

If you need a furnace repaired or an air conditioner serviced, we'll send a local technician out to diagnose the specific problem and recommend solutions for you and your family. There will be a diagnostic fee for the visit, and any specific repairs will be an additional charge. If replacing your system is the best solution, the fee for the diagnosis will be credited toward the purchase and install of a new system.
High-efficiency condensing furnaces (90% AFUE and above) are a bit more complex than conventional furnaces. The main differences between a conventional and condensing furnace are the heat exchanger technology used to extract heat from the combustion process and the method used to exhaust the combustion gases. In these ways, the furnaces are very different. The condensing furnace does not have a significantly more efficient combustion process than does a conventional furnace; both use gas burners with electronic ignition. The difference lies in that the condensing furnace has a more efficient heat extraction process after combustion.
×