Most modern air-conditioning systems feature a dehumidification cycle during which the compressor runs while the fan is slowed as much as possible[citation needed] to reduce the evaporator temperature and therefore condense more water. When the temperature falls below a threshold, both the fan and compressor are shut off to mitigate further temperature drops;[clarification needed] this prevents moisture on the evaporator from being blown back into the room.[citation needed] When the temperature rises again,[clarification needed] the compressor restarts and the fan returns to low speed.
With the ice and snow in the Charlotte area this week be sure to look at your outdoor unit for ice or snow buildup, especially if you have a heat pump. You can carefully attempt to remove any frozen buildup by pouring warm water over the unit to melt the snow and ice. Do not use any sharp objects to pick or knock the ice off, this could cause severe damage to the unit
Before you rush into replacements, installations, or service for your heating and cooling systems, it’s important to get a trustworthy estimate. With Wm. Price Heating & Cooling, you’ll receive knowledgeable recommendations based on our years of experience and high quality technical training. We analyze your space and needs, and provide an estimate you can count on to be the best. Contact us today to schedule your estimate!
With the split system, the evaporator coil is connected to a remote condenser unit using refrigerant piping between an indoor and outdoor unit instead of ducting air directly from the outdoor unit. Indoor units with directional vents mount onto walls, suspended from ceilings, or fit into the ceiling. Other indoor units mount inside the ceiling cavity, so that short lengths of duct handle air from the indoor unit to vents or diffusers around the rooms.
With a modern heat pump system installation, you’ll enjoy benefits such as exceptional efficiency and maximum temperature control all year round. These innovative systems combine both heating and cooling into one compact system. The technicians from Sky Heating & Air Conditioning are highly qualified and experienced in heat pump maintenance, repairs, and installations, so you can feel confident in our services. We specialize in WaterFurnace geothermal heat pump systems, which offer unprecedented efficiency and energy savings. Browse our website or give us a call today to learn even more!
In variable climates, the system may include a reversing valve that switches from heating in winter to cooling in summer. By reversing the flow of refrigerant, the heat pump refrigeration cycle is changed from cooling to heating or vice versa. This allows a facility to be heated and cooled by a single piece of equipment by the same means, and with the same hardware.
Some systems include an "economizer mode", which is sometimes called a "free-cooling mode". When economizing, the control system will open (fully or partially) the outside air damper and close (fully or partially) the return air damper. This will cause fresh, outside air to be supplied to the system. When the outside air is cooler than the demanded cool air, this will allow the demand to be met without using the mechanical supply of cooling (typically chilled water or a direct expansion "DX" unit), thus saving energy. The control system can compare the temperature of the outside air vs. return air, or it can compare the enthalpy of the air, as is frequently done in climates where humidity is more of an issue. In both cases, the outside air must be less energetic than the return air for the system to enter the economizer mode.
Absorption heat pumps are a kind of air-source heat pump, but they do not depend on electricity to power them. Instead, gas, solar power, or heated water is used as a main power source. An absorption pump dissolves ammonia gas in water, which gives off heat. Next, the water and ammonia mixture is depressurized to induce boiling, and the ammonia is boiled off, which absorbs heat from the outdoor air.[citation needed]

In addition, if water is condensed in the room, the amount of heat previously needed to evaporate that water also is re-released in the room (the latent heat of vaporization). The dehumidification process is the inverse of adding water to the room with an evaporative cooler, and instead releases heat. Therefore, an in-room dehumidifier always will warm the room and reduce the relative humidity indirectly, as well as reducing the humidity directly by condensing and removing water.


Most Michigan HVAC repair companies will often charge a “Travel Charge” or “Diagnosis Fee.” Randazzo calls this fee simply, a “Service Call Fee.” This will be the minimum cost of the repair. It is not recommended to judge a company on how expensive or how cheap their service rates are. In most cases, with larger companies the rates will be higher. This is not because they may have more overhead but simply because of the quality and preparedness of the service that will be preformed.
The fan limit switch controls the furnace blower. The fan limit switch has three settings: “Fan On”, “Fan Off”, and “Limit”. In the “Fan Off” setting, the blower will only operate if there is warm air in the plenum to prevent cool air from blowing into the home. The “Fan On” setting will keep the blower operating even after the burner has shutdown, making sure that all of the hot air produced is circulated. The “Limit” setting is a safety control that will turn the burner off in the rare event that the air in the warm air plenum reaches an unsafe temperature. This may be the case if ducts are blocked or if the system controls are malfunctioning.
Talk to your HVAC repair contractor about options to make HVAC repair costs more affordable. Many contractors offer financing options to assist customers in this very position, as well as payment plans. HVAC companies know HVAC repair costs can come as quite a shock in some scenarios, and want to help you get the repairs your system needs to preserve your comfort and safety.

We maintain a complaint-free A+ rating with the Better Business Bureau, and are a 2017 Better Business Award Winner for ethics. Comfort Plus Services has achieved recognition as a Carrier Factory Authorized Dealer for sound business practices, technical expertise, and customer approval ratings. We simplify the demands of local weather and a comfortable home with upfront pricing, honest estimates, comprehensive service plans, and Emergency Service throughout Salisbury, Fruitland, Delmar, Hebron, Eden, Delmar, Parsonsburg, Pittsville, Mardela Springs, Princess Anne & Willards, MD and more. See our Areas of Service. For new home comfort systems, Comfort Plus Services protects your interests with a 100% money back guarantee. We provide expert service you can trust.
In the case of heated water or steam, piping is used to transport the heat to the rooms. Most modern hot water boiler heating systems have a circulator, which is a pump, to move hot water through the distribution system (as opposed to older gravity-fed systems). The heat can be transferred to the surrounding air using radiators, hot water coils (hydro-air), or other heat exchangers. The radiators may be mounted on walls or installed within the floor to produce floor heat.
Has another company told you that your furnace has a cracked heat exchanger?  The heat exchanger is the heart of your furnace. Its failure can result in a dangerous situation for your home and the best solution is usually a new furnace.  Because of these issues, Bonney takes this situation very seriously.  We will offer you proof of the cracked heat exchanger in the form of a picture from our video inspection camera or a report from our exhaust gas analyzer, before we make our recommendation.
If the condenser coils are clogged, the compressor can overheat and shut down. You’ll experience intermittent periods of minimal cooling, followed by no cooling. Even if you’re “sure” the condenser coils are clean, clean them again. Turn off the power. Flip the air conditioning service and furnace circuit breakers in your main electrical panel to the “Off” position. Next, turn off the power switch right at the furnace or air handler. Then yank the disconnect block (Photo 1) and clean the condenser coils (Photo 2). If the air conditioning service still doesn’t work properly after you’ve cleaned the condenser coils, installed a new filter and opened all the supply vents, proceed with the following repairs.
When your gas furnace isn’t blowing hot air, the issue could be due to a faulty pilot light or broken ignitor. Remove the furnace cover panel and visually inspect whether you can see a flame from the pilot light. A natural gas furnace will be blue and yellow in color, and a propane furnace should have a bluish green flame with a yellow tip. If you can see a flame and it appears normal, the issue could be related to the furnace blower motor or other complex furnace parts. If the flame appears low or non-existent, it’s best to contact an experienced furnace repair company. Remember to never touch any open wires; contact a professional.
As an Atlanta resident, you’re well aware that the weather in our area can go through extremes of both hot and cold throughout the year, taxing your heating and cooling system to its limits. You’ll likely encounter the need for repair or replacement at some point. If you need HVAC installation, HVAC maintenance, or HVAC service and repair, R.S. Andrews is the most trusted name in Atlanta.

If the AC doesn’t turn off, it may be time to clean the condensing unit. Dirty condenser coils won’t give off heat efficiently and will keep the unit running.  Another possibility: The contacts on the outdoor run relay may have welded together—something that can happen over time because of frequent electrical arcing at the relay. Before checking the run relay, turn off the power to the furnace and the condensing unit. Next, disassemble the relay and pry apart the contacts. This should do the trick until you buy a replacement—which you should do soon.


Air conditioner problems tend to complicate over time. A simple problem can turn into a system breaking catastrophe if left to its own devices. If you suspect that you need any kind of AC repair in Denver, then give us a call. Here at Brothers Plumbing Heating And Electric, our Denver AC repair technicians are always standing by to give you a hand with your air conditioning problems. If you would like to learn more about the energy efficiency of cooling systems, then click HERE.
The main problem when installing a multi-split system is the laying of long refrigerant lines for connecting the external unit to the internal ones. While installing a separate split system, workers try to locate both units opposite to each other, where the length of the line is minimal. Installing a multi-split system creates more difficulties, since some of indoor units can be located far from the outside. The first models of multi-split systems had one common control system that did not allow you to set the air conditioning individually for each room. However, now the market has a wide selection of multi-split systems, in which the functional characteristics of indoor units operate separately from each other.
The first air conditioners and refrigerators employed toxic or flammable gases, such as ammonia, methyl chloride, or propane, that could result in fatal accidents when they leaked. Thomas Midgley, Jr. created the first non-flammable, non-toxic chlorofluorocarbon gas, Freon, in 1928. The name is a trademark name owned by DuPont for any chlorofluorocarbon (CFC), hydrochlorofluorocarbon (HCFC), or hydrofluorocarbon (HFC) refrigerant. The refrigerant names include a number indicating the molecular composition (e.g., R-11, R-12, R-22, R-134A). The blend most used in direct-expansion home and building comfort cooling is an HCFC known as chlorodifluoromethane (R-22).
A heat pump is an air conditioner in which the refrigeration cycle can be reversed, producing heating instead of cooling in the indoor environment. They are also commonly referred to as a "reverse cycle air conditioner". The heat pump is significantly more energy efficient than electric resistance heating. Some homeowners elect to have a heat pump system installed as a feature of a central air conditioner. When the heat pump is in heating mode, the indoor evaporator coil switches roles and becomes the condenser coil, producing heat. The outdoor condenser unit also switches roles to serve as the evaporator, and discharges cold air (colder than the ambient outdoor air).
Air conditioners can create a lot of water because they remove moisture from the air. To get rid of this, they have a [usually plastic] drain pipe that comes out of the side of the air handler. Over time, algae can block this pipe and, when it does, the AC won’t work. In fact, some condensate drains have a float switch that won’t let the AC run if water backs-up. Water can also puddle around the unit or flood the area. To deal with condensate problems, please see Air Conditioner Leaks Water, below.
If your air conditioner is old, consider buying an energy-efficient model. Look for the ENERGY STAR® and EnergyGuide labels — qualified central units are about 15% more efficient than standard models. New residential central air conditioner standards went into effect on January 1, 2015; see the efficiency standards for central air conditioners for details, and consider purchasing a system with a higher SEER than the minimum for greater savings.
When the time comes to schedule furnace repairs, you want a team you can trust. Keeping your home warm and comfortable is important for you and your family, which is why you should rely on the highly-trained team of technicians at Horizon Services. Our techs undergo at least 150 hours of technical training every year and are up-to-date on the latest, most advanced techniques in the trade. We also background-check all of our employees to ensure your complete comfort and safety. When you call on us for furnace repair, we will arrive on-time and on schedule, ready to resolve the issue as quickly as possible.
×