Absorption refrigerator Air barrier Air conditioning Antifreeze Automobile air conditioning Autonomous building Building insulation materials Central heating Central solar heating Chilled beam Chilled water Constant air volume (CAV) Coolant Dedicated outdoor air system (DOAS) Deep water source cooling Demand-controlled ventilation (DCV) Displacement ventilation District cooling District heating Electric heating Energy recovery ventilation (ERV) Firestop Forced-air Forced-air gas Free cooling Heat recovery ventilation (HRV) Hybrid heat Hydronics HVAC Ice storage air conditioning Kitchen ventilation Mixed-mode ventilation Microgeneration Natural ventilation Passive cooling Passive house Radiant heating and cooling system Radiant cooling Radiant heating Radon mitigation Refrigeration Renewable heat Room air distribution Solar air heat Solar combisystem Solar cooling Solar heating Thermal insulation Underfloor air distribution Underfloor heating Vapor barrier Vapor-compression refrigeration (VCRS) Variable air volume (VAV) Variable refrigerant flow (VRF) Ventilation

For new installation or upgrades to heating/cooling systems, including geothermal and ductless units, the team from Mountain Valley Home Comfort delivers exceptional return from your investment. We stand behind new system installation with a five year labor warranty, and handle every job to higher standards across New Market, Mount Jackson, Timberville, Broadway, Edinburg, Luray, Stanley, Fulks Run, Basye & Harrisonburg, VA.


In the event of an emergency with your residential heating and cooling system, we understand that you simply cannot wait! At R.S. Andrews, we take your comfort and well-being seriously and are proud to offer our emergency HVAC repair at any hour, on any day—including weekends! We provide only the highest quality services to ensure your needs are met!
The condensed, pressurized, and still usually somewhat hot liquid refrigerant is next routed through an expansion valve (often nothing more than a pinhole in the system's copper tubing) where it undergoes an abrupt reduction in pressure. That pressure reduction results in flash evaporation of a part of the liquid refrigerant, greatly lowering its temperature. The cold refrigerant is then routed through the evaporator. A fan blows the interior warm air (which is to be cooled) across the evaporator, causing the liquid part of the cold refrigerant mixture to evaporate as well, further lowering the temperature. The warm air is therefore cooled and is pumped by an exhaust fan/ blower into the room. To complete the refrigeration cycle, the refrigerant vapor is routed back into the compressor. In order for the process to have any efficiency, the cooling/evaporative portion of the system must be separated by some kind of physical barrier from the heating/condensing portion, and each portion must have its own fan to circulate its own "kind" of air (either the hot air or the cool air).
Whether in your home or business, we can get your air conditioner working again in no time! Randazzo Heating, Cooling, and Fireplaces has a staff of experienced technicians who will come to your rescue! We can also keep you updated on when your air conditioner should have routine maintenance inspections, so you can keep it performing at optimum efficiency.
The use of CFC as a refrigerant was once common, including the refrigerants R-11 and R-12 (sold under the brand name Freon-12). Freon refrigerants were commonly used during the 20th century in air conditioners due to their superior stability and safety properties. When they are released accidentally or deliberately, these chlorine-bearing refrigerants eventually reach the upper atmosphere.[60] Once the refrigerant reaches the stratosphere, UV radiation from the Sun homolytically cleaves the chlorine-carbon bond, yielding a chlorine radical. These chlorine radicals catalyze the breakdown of ozone into diatomic oxygen, depleting the ozone layer that shields the Earth's surface from strong UV radiation. Each chlorine radical remains active as a catalyst until it binds with another radical, forming a stable molecule and quenching the chain reaction.
At Horizon Services, we strive to provide all of our customers with the peace of mind that comes from knowing that you have a skilled team on-call for any AC emergencies that may arise. We have more than 300 fully stocked trucks ready to go at a moment's notice. Our Horizon technicians undergo rigorous training, including a mandatory 150 hours of training every year, to ensure that they're always up to date on the latest techniques and HVAC technology. Plus, we perform extensive background checks, including drug and criminal checks, on all of our employees so you don't have to worry about letting a stranger into your home when your AC breaks down in the middle of the night. When you're dealing with an air conditioning emergency, trust the experts at Horizon Services!

Central, "all-air" air-conditioning systems (or package systems) with a combined outdoor condenser/evaporator unit are often installed in North American residences, offices, and public buildings, but are difficult to retrofit (install in a building that was not designed to receive it) because of the bulky air ducts required. (Minisplit ductless systems are used in these situations.) Outside of North America, packaged systems are only used in limited applications involving large indoor space such as stadiums, theatres or exhibition halls.

Evaporative coolers, sometimes called "swamp coolers", do not have a compressor or condenser. Liquid water is evaporated on the cooling fins, releasing the vapor into the cooled area. Evaporating water absorbs a significant amount of heat, the latent heat of vaporisation, cooling the air. Humans and animals use the same mechanism to cool themselves by sweating.


The standards do not require you to change your existing central air conditioning units, and replacement parts and services should still be available for your home’s systems. The “lifespan” of a central air conditioner is about 15 to 20 years. Manufacturers typically continue to support existing equipment by making replacement parts available and honoring maintenance contracts after the new standard goes into effect.
If you need a furnace repaired or an air conditioner serviced, we'll send a local technician out to diagnose the specific problem and recommend solutions for you and your family. There will be a diagnostic fee for the visit, and any specific repairs will be an additional charge. If replacing your system is the best solution, the fee for the diagnosis will be credited toward the purchase and install of a new system.
In hot weather, air conditioning can prevent heat stroke, dehydration from excessive sweating and other problems related to hyperthermia. Heat waves are the most lethal type of weather phenomenon in developed countries. Air conditioning (including filtration, humidification, cooling and disinfection) can be used to provide a clean, safe, hypoallergenic atmosphere in hospital operating rooms and other environments where proper atmosphere is critical to patient safety and well-being. It is sometimes recommended for home use by people with allergies.
SEER is related to the coefficient of performance (COP) commonly used in thermodynamics and also to the Energy Efficiency Ratio (EER). The EER is the efficiency rating for the equipment at a particular pair of external and internal temperatures, while SEER is calculated over a whole range of external temperatures (i.e., the temperature distribution for the geographical location of the SEER test). SEER is unusual in that it is composed of an Imperial unit divided by an SI unit. The COP is a ratio with the same metric units of energy (joules) in both the numerator and denominator. They cancel out, leaving a dimensionless quantity. Formulas for the approximate conversion between SEER and EER or COP are available.[34]
For regular upkeep, Bay Area Air Conditioning, Inc. draws from 43 years of practical experience.  We’ve learned that an intense Higher Performance Tune Up and Cleaning effectively restores the capacity, efficiency, sound levels, and overall performance of all makes and models of HVAC equipment to peak condition.  Should you experience a problem, we offer free second options, cost-effective recommendations, and prompt repairs.  We stand behind all new installation projects with our ten year parts and labor warranty, and verify performance data to ensure quality of operation. We aim to be the best HVAC company in Crystal River, FL and Central Florida.

The thermocouple is a copper rod that the pilot flame heats-up. When it gets hot enough, the thermocouple signals that there is enough heat to burn the gas fuel being released into the appliance—and so it allows the gas to be released to the burners. In some cases where the pilot light won’t stay lit, the thermocouple needs to be adjusted or replaced. This is generally a job for a professional.
High-efficiency condensing furnaces (90% AFUE and above) are a bit more complex than conventional furnaces. The main differences between a conventional and condensing furnace are the heat exchanger technology used to extract heat from the combustion process and the method used to exhaust the combustion gases. In these ways, the furnaces are very different. The condensing furnace does not have a significantly more efficient combustion process than does a conventional furnace; both use gas burners with electronic ignition. The difference lies in that the condensing furnace has a more efficient heat extraction process after combustion.
×