Let Fayette Furnace help you step up your home efficiency with a wide range of air conditioning and heating products, services and our skilled team of technicians. An employee owned company since 1920; we pride ourselves on continuing a longstanding tradition of honesty, professionalism and expertise. Call and ask about our service maintenance agreements to save money on maintenance and emergency calls. A yearly service is recommended per the manufacturer’s warranty on the equipment.

Our skilled technicians arrive prepared to handle the scope of even complex malfunctions, with all makes and models of heating and cooling equipment, most often resolving the problem on the spot.  For all your HVAC service, repairs, and installations in Livermore, CA, Pleasanton, CA & Dublin, CA, call the team from Miller’s Air Conditioning & Heating!


SEER is related to the coefficient of performance (COP) commonly used in thermodynamics and also to the Energy Efficiency Ratio (EER). The EER is the efficiency rating for the equipment at a particular pair of external and internal temperatures, while SEER is calculated over a whole range of external temperatures (i.e., the temperature distribution for the geographical location of the SEER test). SEER is unusual in that it is composed of an Imperial unit divided by an SI unit. The COP is a ratio with the same metric units of energy (joules) in both the numerator and denominator. They cancel out, leaving a dimensionless quantity. Formulas for the approximate conversion between SEER and EER or COP are available.[34]
If your air conditioning is blowing warm air—or not working at all—it's time to call in the experts. After all, we're not just talking about an uncomfortable afternoon on a hot day: we're talking about your happiness at home, and a problem that may cause extensive damage to your system if not addressed quickly. That's why it's smart to catch problems early before they become expensive to address.
Before calling to schedule your appointment, it may be helpful to familiarize yourself with the air conditioning equipment that you have. Make sure you know at least the brand name, the model and the approximate age of the system, as well as any warranties that may be in effect—and read through our AC FAQ to see if any of your symptoms sound familiar.
At Sky Heating & Air Conditioning, we understand that HVAC services can really hurt your budget. Many times, you don’t expect to make such large purchases until an emergency arises. We never want you to feel that you cannot afford your comfort and safety. We offer flexible financing options through the Home Project credit card from Wells Fargo, with approved credit. Head over to our financing page to apply, or give us a call for more information!
Engineers have pointed out some areas where efficiency of the existing hardware could be improved. For example, the fan blades used to move the air are usually stamped from sheet metal, an economical method of manufacture, but as a result they are not aerodynamically efficient. A well-designed blade could reduce electrical power required to move the air by a third.[26]
Though forced-air furnaces are normally quite reliable, they can break down. To avoid break downs, it pays to know how to take care of your furnace and fix it when something goes wrong. Inevitably, a furnace stops working when you need it most. Consequently, fixing becomes urgent very quickly. The following instructions will help. With a little do-it-yourself experience and the proper guidance, you can troubleshoot and repair a variety of furnace problems yourself.
In very dry climates, evaporative coolers, sometimes referred to as swamp coolers or desert coolers, are popular for improving coolness during hot weather. An evaporative cooler is a device that draws outside air through a wet pad, such as a large sponge soaked with water. The sensible heat of the incoming air, as measured by a dry bulb thermometer, is reduced. The temperature of the incoming air is reduced, but it is also more humid, so the total heat (sensible heat plus latent heat) is unchanged. Some of the sensible heat of the entering air is converted to latent heat by the evaporation of water in the wet cooler pads. If the entering air is dry enough, the results can be quite substantial.
Air conditioning and refrigeration are provided through the removal of heat. Heat can be removed through radiation, convection, or conduction. Refrigeration conduction media such as water, air, ice, and chemicals are referred to as refrigerants. A refrigerant is employed either in a heat pump system in which a compressor is used to drive thermodynamic refrigeration cycle, or in a free cooling system which uses pumps to circulate a cool refrigerant (typically water or a glycol mix).
Evaporative coolers, sometimes called "swamp coolers", do not have a compressor or condenser. Liquid water is evaporated on the cooling fins, releasing the vapor into the cooled area. Evaporating water absorbs a significant amount of heat, the latent heat of vaporisation, cooling the air. Humans and animals use the same mechanism to cool themselves by sweating.

The use of CFC as a refrigerant was once common, including the refrigerants R-11 and R-12 (sold under the brand name Freon-12). Freon refrigerants were commonly used during the 20th century in air conditioners due to their superior stability and safety properties. When they are released accidentally or deliberately, these chlorine-bearing refrigerants eventually reach the upper atmosphere.[60] Once the refrigerant reaches the stratosphere, UV radiation from the Sun homolytically cleaves the chlorine-carbon bond, yielding a chlorine radical. These chlorine radicals catalyze the breakdown of ozone into diatomic oxygen, depleting the ozone layer that shields the Earth's surface from strong UV radiation. Each chlorine radical remains active as a catalyst until it binds with another radical, forming a stable molecule and quenching the chain reaction.
We provide plumbing service to Atlanta and the surrounding communities, including: Acworth, Alpharetta, Austell, Avondale Estates, Brookhaven, Buford, Chamblee, Clarkston, Conyers, Cumming, Dacula, Decatur, Doraville, Douglasville, Duluth, Dunwoody, Fayetteville, Forest Park, Grayson, Holly Springs, Johns Creek, Kennesaw, Lawrenceville, Lilburn, Lithonia, Loganville, Marietta, Milton, Morrow, Norcross, Peach Tree City, Pine Lake, Powder Springs, Roswell, Sandy Springs, Snellville, Stone Mountain, Sugar Hill, Suwanee, and Woodstock, GA.
The use of furnaces, space heaters, and boilers as a method of indoor heating could result in incomplete combustion and the emission of carbon monoxide, nitrogen oxides, formaldehyde, volatile organic compounds, and other combustion byproducts. Incomplete combustion occurs when there is insufficient oxygen; the inputs are fuels containing various contaminants and the outputs are harmful byproducts, most dangerously carbon monoxide, which is a tasteless and odorless gas with serious adverse health effects.[14]
Mountain Valley Home Comfort provides expert heating and cooling services in Virginia’s Shenandoah Valley.  Our team of licensed, trained, and experienced professionals handle new installation, retrofit projects, seasonal maintenance and challenging repairs.  When you call on Mountain Valley Home Comfort at (540) 740-3844, we target sustainable solutions to temperature control, saving you time and money, and protecting comfort and budget. Personalizing our services to meet your needs, we ensure the right answer to any requirement.  With organized job sites, swift response, and quick turnaround, our professionals resolve any difficulty and take the best possible care of your essential HVAC equipment.

Dichlorodifluoromethane (R-12) was the most common blend used in automobiles in the U.S. until 1994, when most designs changed to R-134A due to the ozone-depleting potential of R-12. R-11 and R-12 are no longer manufactured in the U.S. for this type of application, so the only source for air-conditioning repair purposes is the cleaned and purified gas recovered from other air conditioner systems. Several non-ozone-depleting refrigerants have been developed as alternatives, including R-410A. It was first commercially used by Carrier Corp. under the brand name Puron.[citation needed]


Refrigeration air conditioning equipment usually reduces the absolute humidity of the air processed by the system. The relatively cold (below the dewpoint) evaporator coil condenses water vapor from the processed air, much like an ice-cold drink will condense water on the outside of a glass. Therefore, water vapor is removed from the cooled air and the relative humidity in the room is lowered. The water is usually sent to a drain or may simply drip onto the ground outdoors. The heat is rejected by the condenser which is located outside of room to be cooled.

Many homeowners don't often think of the state of their furnace—that is until, the first cold day of the year comes around and the furnace won't turn on or only blows cold air. Keeping an eye out for common signs of trouble can help you avoid a complete furnace breakdown. Addressing any issues early on can also help you avoid most extensive (and therefore, more expensive) repairs down the road.
×