In order to make your everyday life easier and more enjoyable, Sky Heating & Air Conditioning specializes in state-of-the-art heating and cooling technology, partnering with Trane, Mitsubishi, and Waterfurnace.  We bring you HVAC solutions that represent the best the industry has to offer, ensuring long-term performance and satisfaction.  Whether you’re looking for the design/build of a new system, replacement, or hoping to cut costs and enhance convenience, we answer with proven products.  Our qualified HVAC technicians help you determine the ideal solution for your exact requirements, and make sure you’re happy with every step of the process.  From ductless HVAC to geothermal heating and cooling systems, we offer a wide selection of options and comprehensive services to answer any type of challenge.  Call on Sky Heating & Air Conditioning and let us exceed your expectations today!
In 1758, Benjamin Franklin and John Hadley, a chemistry professor at Cambridge University, conducted an experiment to explore the principle of evaporation as a means to rapidly cool an object. Franklin and Hadley confirmed that evaporation of highly volatile liquids (such as alcohol and ether) could be used to drive down the temperature of an object past the freezing point of water. They conducted their experiment with the bulb of a mercury thermometer as their object and with a bellows used to speed up the evaporation. They lowered the temperature of the thermometer bulb down to −14 °C (7 °F) while the ambient temperature was 18 °C (64 °F). Franklin noted that, soon after they passed the freezing point of water 0 °C (32 °F), a thin film of ice formed on the surface of the thermometer's bulb and that the ice mass was about 6 mm (1⁄4 in) thick when they stopped the experiment upon reaching −14 °C (7 °F). Franklin concluded: "From this experiment one may see the possibility of freezing a man to death on a warm summer's day."[9]
The thermocouple is a copper rod that the pilot flame heats-up. When it gets hot enough, the thermocouple signals that there is enough heat to burn the gas fuel being released into the appliance—and so it allows the gas to be released to the burners. In some cases where the pilot light won’t stay lit, the thermocouple needs to be adjusted or replaced. This is generally a job for a professional.
As your trusted HVAC service experts since 1960, Miller's Air Conditioning & Heating was established before Livermore became an official city.  We have a long-term commitment to the local community and have built solid relationships across generations of families.  Family owned and operated, we recognize the importance of an HVAC provider you can always depend on to serve your best interests.  At Miller's Air Conditioning & Heating we uphold exacting standards of quality, from the products we recommend and install, to the integrity of workmanship.  By refusing to settle, we provide a greater return from all of our services, including new system installation, replacement, seasonal maintenance, and repair of air conditioners, heat pumps, furnaces, ductless units, and attic fans.  Whether you’re a first-time homeowner or dissatisfied with the contractors you’ve tried in the past, we’ll make sure Miller's Air Conditioning & Heating satisfies your every expectation.
AC air handler squealing or grinding noises. Though most air handlers have direct-drive motors, some older units may be belt-driven. Squealing sounds from a belt-drive air handler generally occur when the belt that connects the motor to the blower slips. In most cases, the belt is improperly aligned or worn and needs replacement. Follow the instructions above under Air Conditioner Not Blowing Air and refer to your owner’s manual.
Our licensed HVAC Dallas Air Conditioning technicians are experts in air conditioning, heating & cooling technology and the latest innovations in green technology, including the installation of Energy Star certified products and the use of Ozone friendly refrigerants. Residential customers depend on Berkeys for timely, quality, and affordable air conditioning repair, maintenance, and installation solutions in Dallas. Read our Air Conditioning Reviews.
All modern air conditioning systems, even small window package units, are equipped with internal air filters. These are generally of a lightweight gauzy material, and must be replaced or washed as conditions warrant. For example, a building in a high dust environment, or a home with furry pets, will need to have the filters changed more often than buildings without these dirt loads. Failure to replace these filters as needed will contribute to a lower heat exchange rate, resulting in wasted energy, shortened equipment life, and higher energy bills; low air flow can result in iced-over evaporator coils, which can completely stop air flow. Additionally, very dirty or plugged filters can cause overheating during a heating cycle, and can result in damage to the system or even fire.
In addition, if water is condensed in the room, the amount of heat previously needed to evaporate that water also is re-released in the room (the latent heat of vaporization). The dehumidification process is the inverse of adding water to the room with an evaporative cooler, and instead releases heat. Therefore, an in-room dehumidifier always will warm the room and reduce the relative humidity indirectly, as well as reducing the humidity directly by condensing and removing water.

Ductwork pinging or popping. If you hear a pinging or popping sound coming from metal ductwork, this may be caused by thermal expansion or by air blowing past a loose flap of metal. Track along the duct runs, listening for the sound. If you find it, make a small dent in the sheet metal to provide a more rigid surface that’s less likely to move as it heats and cools.
Furnaces and thermostats are not mix-and-match appliances. Using the wrong type of thermostat with a furnace will cause operating problems and can be dangerous. Although thermostats look similar, they are designed very differently. There are numerous types of heating systems and thermostat systems and they need to be coordinated for safe and proper operation. There are three types of thermostat systems used today: millivoltage, low voltage, and line voltage.​
×