Packaged terminal air conditioner (PTAC) systems are also known as wall-split air conditioning systems.[36] They are ductless systems. PTACs, which are frequently used in hotels, have two separate units (terminal packages), the evaporative unit on the interior and the condensing unit on the exterior, with an opening passing through the wall and connecting them. This minimizes the interior system footprint and allows each room to be adjusted independently. PTAC systems may be adapted to provide heating in cold weather, either directly by using an electric strip, gas, or other heater, or by reversing the refrigerant flow to heat the interior and draw heat from the exterior air, converting the air conditioner into a heat pump. While room air conditioning provides maximum flexibility, when used to cool many rooms at a time it is generally more expensive than central air conditioning.

Start with your utility company; they can help a great deal. Comparing previous bills isn't always a good measure, as the weather is never exactly the same month to month. Instead, if you take your energy bill and divide it by the square footage of livable space in your home, don't count areas like unfinished garages or basements -- you can calculate how much you are spending to heat or cool each square foot of your home. Your energy provider can tell you what the average cost per square foot is in your region for that same period of time so you can compare apples to apples.
Poorly maintained water cooling towers can promote the growth and spread of microorganisms,[55] such as Legionella pneumophila, the infectious agent responsible for Legionnaires' disease, or thermophilic actinomycetes. As long as the cooling tower is kept clean (usually by means of a chlorine treatment), these health hazards can be avoided or reduced. Excessive air conditioning can have a negative effect on skin, causing it to dry out, and can also cause dehydration.[citation needed]
Ductwork pinging or popping. If you hear a pinging or popping sound coming from metal ductwork, this may be caused by thermal expansion or by air blowing past a loose flap of metal. Track along the duct runs, listening for the sound. If you find it, make a small dent in the sheet metal to provide a more rigid surface that’s less likely to move as it heats and cools.
SEER is related to the coefficient of performance (COP) commonly used in thermodynamics and also to the Energy Efficiency Ratio (EER). The EER is the efficiency rating for the equipment at a particular pair of external and internal temperatures, while SEER is calculated over a whole range of external temperatures (i.e., the temperature distribution for the geographical location of the SEER test). SEER is unusual in that it is composed of an Imperial unit divided by an SI unit. The COP is a ratio with the same metric units of energy (joules) in both the numerator and denominator. They cancel out, leaving a dimensionless quantity. Formulas for the approximate conversion between SEER and EER or COP are available.[34]
Located conveniently in Spokane, we know how painful it can be to wait around for weeks for an appointment. Unlike other companies, we’ll do everything that we can to get to you quickly, so that your family can sleep comfortably. Give us a call today, you’ve got nothing to lose, and let us tell you more about the exceptional customer service that we’ve offered to our clients for years.
“Accurate, extremely thorough and knowledgeable quote for a complete replacement AC system for my home. Installation was neat and completed in a day as promised. Everyone was on the same page regarding the entire transaction and all technicians were polite and helpful. No question I would use them for any further AC related problems in the future.” – Daryl

We don’t just repair and replace existing equipment, either. We also do upgrades. Summers get hot and winters get cold here in Kansas City, KS. If your water heater, furnace, or AC unit just isn’t cutting it, we can install a new one. We always offer the best price on new equipment, including easy financing options. Call us for a free estimate, and if you decide the price is right, we’ll send out one of our expert technicians to install your furnace, AC or water heater.
Sky Heating & Air Conditioning answers any comfort challenge with straightforward, satisfying solutions. We get rid of the need for labor-intensive renovation. We don’t tear down walls or ceilings, steal precious closet space for the installation of ductwork, or cause mess or damage. With the installation of a ductless HVAC system, we answer your temperature control requirements with wonderful simplicity.
The Denver AC compressor repair and replacement experts here at Brothers are always just a phone call away. Your AC compressor is the most important part of your air conditioning system, and without it the entire system will cease to function. If your system is showing any of the following signs, then it is time to contact our Denver AC compressor repair experts:

Most modern air-conditioning systems feature a dehumidification cycle during which the compressor runs while the fan is slowed as much as possible[citation needed] to reduce the evaporator temperature and therefore condense more water. When the temperature falls below a threshold, both the fan and compressor are shut off to mitigate further temperature drops;[clarification needed] this prevents moisture on the evaporator from being blown back into the room.[citation needed] When the temperature rises again,[clarification needed] the compressor restarts and the fan returns to low speed.

The most recognized standards for HVAC design are based on ASHRAE data. The most general of four volumes of the ASHRAE Handbook is Fundamentals; it includes heating and cooling calculations. Each volume of the ASHRAE Handbook is updated every four years. The design professional must consult ASHRAE data for the standards of design and care as the typical building codes provide little to no information on HVAC design practices; codes such as the UMC and IMC do include much detail on installation requirements, however. Other useful reference materials include items from SMACNA, ACGIH, and technical trade journals.

At Comfort Plus Services, we set ourselves apart from the rest through quality customer service across Salisbury, MD and surrounding areas. See our Areas of Service. Our strength is in our high standards of job performance and fully trained professionals.  Our team upholds a proven reputation and is continually motivated to achieve excellence in every service we provide.
Most modern air-conditioning systems feature a dehumidification cycle during which the compressor runs while the fan is slowed as much as possible[citation needed] to reduce the evaporator temperature and therefore condense more water. When the temperature falls below a threshold, both the fan and compressor are shut off to mitigate further temperature drops;[clarification needed] this prevents moisture on the evaporator from being blown back into the room.[citation needed] When the temperature rises again,[clarification needed] the compressor restarts and the fan returns to low speed.
The HVAC industry is a worldwide enterprise, with roles including operation and maintenance, system design and construction, equipment manufacturing and sales, and in education and research. The HVAC industry was historically regulated by the manufacturers of HVAC equipment, but regulating and standards organizations such as HARDI, ASHRAE, SMACNA, ACCA, Uniform Mechanical Code, International Mechanical Code, and AMCA have been established to support the industry and encourage high standards and achievement.
Absorption heat pumps are a kind of air-source heat pump, but they do not depend on electricity to power them. Instead, gas, solar power, or heated water is used as a main power source. An absorption pump dissolves ammonia gas in water, which gives off heat. Next, the water and ammonia mixture is depressurized to induce boiling, and the ammonia is boiled off, which absorbs heat from the outdoor air.[citation needed]
In very dry climates, evaporative coolers, sometimes referred to as swamp coolers or desert coolers, are popular for improving coolness during hot weather. An evaporative cooler is a device that draws outside air through a wet pad, such as a large sponge soaked with water. The sensible heat of the incoming air, as measured by a dry bulb thermometer, is reduced. The temperature of the incoming air is reduced, but it is also more humid, so the total heat (sensible heat plus latent heat) is unchanged. Some of the sensible heat of the entering air is converted to latent heat by the evaporation of water in the wet cooler pads. If the entering air is dry enough, the results can be quite substantial.
The icing problem becomes much more severe with lower outdoor temperatures, so heat pumps are commonly installed in tandem with a more conventional form of heating, such as a natural gas or oil furnace, which is used instead of the heat pump during harsher winter temperatures. In this case, the heat pump is used efficiently during the milder temperatures, and the system is switched to the conventional heat source when the outdoor temperature is lower.
We don’t just repair and replace existing equipment, either. We also do upgrades. Summers get hot and winters get cold here in Kansas City, KS. If your water heater, furnace, or AC unit just isn’t cutting it, we can install a new one. We always offer the best price on new equipment, including easy financing options. Call us for a free estimate, and if you decide the price is right, we’ll send out one of our expert technicians to install your furnace, AC or water heater.
×