The thermocouple is a copper rod that the pilot flame heats-up. When it gets hot enough, the thermocouple signals that there is enough heat to burn the gas fuel being released into the appliance—and so it allows the gas to be released to the burners. In some cases where the pilot light won’t stay lit, the thermocouple needs to be adjusted or replaced. This is generally a job for a professional.
The manufacture and use of CFCs has been banned or severely restricted due to concerns about ozone depletion (see also Montreal Protocol).[63][64] In light of these environmental concerns, beginning on November 14, 1994, the U.S. Environmental Protection Agency has restricted the sale, possession and use of refrigerant to only licensed technicians, per rules under sections 608 and 609 of the Clean Air Act.[65]
*We work on all brands: Adams, Aire-Flo, Amana, Arcoaire, Armstrong, Beutler, Bryant, Carrier, Centurion, Coleman, Comfortmaker, Cozy, Daikin, Day & Night, Dayton, Ducane, Emerson, Empire, Evcon, Fedders, Friedrich, Frigidaire, Fujitsu, Gaffers & Statler, General Electric, Gibson, Goldstar, Goodman, GMC, Haier, Heil, Honeywell, Intertherm, Janitrol, Kenmore, Lennox, Luxaire, Maytag, Mitsubishi, Payne, Rheem, Ruud, Samsung, Sanyo, Sears, Sharp, Spartan, Tappan, Tempstar, Thermal Solutions, Trane, Utica, Weatherking, Westinghouse, Whirlpool, Williams, York, and Zephyr.
A multi-split system[44] is a conventional split system, which is divided into two parts (evaporator and condenser) and allows cooling or heating of several rooms with one external unit. In the outdoor unit of this air conditioner there is a more powerful compressor, ports for connecting several traces and automation with locking valves for regulating the volume of refrigerant supplied to the indoor units located in the room.
If your compressor doesn’t have an overload button and you hear it humming or buzzing, poke a screwdriver or stick down through the top grille and try to spin the fan blades clockwise. If doing this gives the fan enough of a boost to get it going, the unit has a faulty capacitor that must be replaced. See How to Test and Replace an AC Run Capacitor, above.
Your furnace's flame sensor is essentially a safety mechanism. As a thin metallic rod in front of the flame inside the unit, it's sole purpose is to confirm that your gas valves only open when a flame actually exists to burn that gas. When the flame sensor stop working, on the other hand, gas leaks can occur. To repair your furnace's flame sensor, expect to spend between $80 and $250. Even a full replacement of this part typically does not go above that range.

Designed to improve manufacturing process control in a printing plant, Carrier's invention controlled not only temperature but also humidity. Carrier used his knowledge of the heating of objects with steam and reversed the process. Instead of sending air through hot coils, he sent it through cold coils (filled with cold water). The air was cooled, and thereby the amount of moisture in the air could be controlled, which in turn made the humidity in the room controllable. The controlled temperature and humidity helped maintain consistent paper dimensions and ink alignment. Later, Carrier's technology was applied to increase productivity in the workplace, and The Carrier Air Conditioning Company of America was formed to meet rising demand. Over time, air conditioning came to be used to improve comfort in homes and automobiles as well. Residential sales expanded dramatically in the 1950s.[citation needed]

In 1995, Germany made CFC refrigerators illegal.[22] DuPont and other companies blocked the refrigerant in the U.S. with the U.S. EPA, disparaging the approach as "that German technology".[21][23] Nevertheless, in 2004, Greenpeace worked with multinational corporations like Coca-Cola and Unilever, and later Pepsico and others, to create a corporate coalition called Refrigerants Naturally!.[22][24] Then, four years later, Ben & Jerry's of Unilever and General Electric began to take steps to support production and use in the U.S.[25] In 2011 the EPA decided in favor of the ozone- and climate-safe refrigerant for U.S. manufacture.[17][26][27]
When your heating and cooling system stops working, you need the help of a reliable, experienced, local service professional that can diagnose the problem and repair your air conditioner or furnace at a fair price. You can count on The Home Depot's licensed and insured heating and cooling professionals for all your heaters, air conditioning units, and any ventilation needs.

Air conditioners can create a lot of water because they remove moisture from the air. To get rid of this, they have a [usually plastic] drain pipe that comes out of the side of the air handler. Over time, algae can block this pipe and, when it does, the AC won’t work. In fact, some condensate drains have a float switch that won’t let the AC run if water backs-up. Water can also puddle around the unit or flood the area. To deal with condensate problems, please see Air Conditioner Leaks Water, below.
With a modern heat pump system installation, you’ll enjoy benefits such as exceptional efficiency and maximum temperature control all year round. These innovative systems combine both heating and cooling into one compact system. The technicians from Sky Heating & Air Conditioning are highly qualified and experienced in heat pump maintenance, repairs, and installations, so you can feel confident in our services. We specialize in WaterFurnace geothermal heat pump systems, which offer unprecedented efficiency and energy savings. Browse our website or give us a call today to learn even more!

The chill of winter can be a scary thought when your furnace needs repair. When the furnace in your home goes on the fritz, you need it fixed right away to keep your family safe and comfortable. Every BGE HOME technician is licensed and adheres to a stringent in-house certification program that guarantees their knowledge, affirms their commitment to the customer, and ensures excellence in completing every furnace repair with the highest level of quality.
×